IEEE Transactions on Very Large Scale Integration (VLSI) Systems

Download PDF

Keywords

Capacitors, Frequency Conversion, Wideband, Receivers, Phase Locked Loops, Permittivity, Oscillators, Dielectric Spectroscopy DS Sensor, Heterodyne Receiver Structure, I Q Mismatch, Quadrature Phase Locked Loop PLL

Abstract

This paper presents a fully integrated broadband biosensor chip for miniaturized dielectric spectroscopy (DS). The proposed biosensor chip consists of wideband exciting signal source and high sensitivity receiver. The exciting signal source consists of a wideband phase-locked loop (PLL) and output drivers. The wideband receiver is composed of low noise amplifier, mixer, and output buffers. The proposed receiver with in-phase ( {I} ) and quadrature-phase ( {Q} ) signals mismatch calibration measures the frequency-dependent S21 magnitude and phase of a microfluidic dielectric sensor. The DS system implements a modified frequency response analysis by converting the biosensor response signal from the RF excitation frequency to low frequency using a passive mixer. Dielectric measurements results of ethanol with the proposed biosensor chip in the range of 5–8 GHz are in excellent agreement (error <1%) with theoretical values. The chip is fabricated in 65-nm CMOS process. The total power consumption is 18 mW with 1.2-V supply.
Like what you’re reading?
Already a member?
Get this article FREE with a new membership!

Related Articles